DP Flow Transmitter

●  apply to all of differential pressure flow sensor    

●  battery powered on-site shows no external 

   power supply

●  the output of super anti-interference design 

   isolation, shielding all distractions 

●  the output pulse, current (4-20mA),485(modbu-

   rtu) signals need external power supply 

●  with temperature and pressure sensor 

●  Gas, steam automatic temperature and 

   pressure compensation

●  range rate is 1:100 (special requirement can be 1:200)

●  accuracy of 0.1 level

●  gas display the parametric such as temperature, pressure, and working 

   conditions flow, standard condition flow, etc.

●  steam display the parametric such as temperature, pressure, and density, 

   mass flow, etc.

Function 

Flow integrating instrument especially adopts micropower singlechip (power 

< = 400uA ), using industry lithium battery DC3.6V supply power, can use 

2-3 years.

Flow integrating instrument using large screen liquid crystal display, it can 

show 6 transient flow, correct to 2 decimal places (0~9999.99m3/h) or 1 

decimal places(0~99999.9m3/h),cumulative flow can show 9 cumulative flow, 

correct to 4 decimal places(0~99999.9999m3)or (0~9999.99999m3)

Technical Parameter

Current Output

> Output two-wire 4-20mA

> Load resistance: 0~600Ω

> Response time: <1s

> Intrinsic erroren: ±0.5%(20℃±5℃)

> Environmental conditions: temperature: -40-85℃, humidity: <85%

> Power supply: ±24VDC±15%

> Power supply:<60Ma

Pulse 

> working voltage: 12VDC~+24VDC

> working current <50mA

> pulse output amplitude Vh=24V, VL<1V.

> frequetance output: 0~1000Hz.

> pulse equivalent: To build the basic unit of the flow that for output, such 

as: accumulate display as 5decimal 0.00000, the pulse equivalent is 

0.00001 M3/P, be 0.01L/P; accumulate display as 4decimal 0.0000, the 

pulse equivalent is 0.0001M3/P, be 0.1L/P; accumulate display as 3decimal 

0.000, the pulse equivalent is 0.001M3/P, be 1L/P.

485 Output 

Agreement: modbus rtu

Message format: Instrument  use 04 package transmit 3 floating point 

variable 12 continuous bytes; 

In proper order is transient flow 6(0-999999, 4 bytes),accumulate flow low 

6(0-999999, 4bytes),accumulate flow high 6 (0-999999, 4types);

accumulate flow low 6: address 30001, (0-999999);

accumulate flow high 6: address 30003, (0-999999);

transient flow 6: address 30005, (0-999999);

Decimal point refer to the display of flow instrument, the flow instrument will 

not transit the decimal point information.

Protection and Hazardous Rating

Protection grade: Ip65

Hazardous rating: ExⅡdCT4(not including acetylene)